Air sealing for unvented cathedral ceiling #green

I am planning a remodel which will add a cathedral ceiling,and there is already an existing cathedral ceiling in another part of my home. Since much of the roof will already be removed this seems like a good time to correctly insulate and air seal.On this site (thank you Martin et.al.) the outer layer of rigid insulation is taped at the seams. On the BuildingScience site (thank you Joe et.al.) the unvented compact roof shows self-sealing membrane over the structural roof deck for an air barrier. Somewhere else I read the suggestion to use tape on the seams of the structural sheathing. All accomplish the same goal but differ in execution. My question is which method is preferred and why? (I'm in climate zone 5 (Denver) with a local snow load design requirement of 30psf. I'm planning on adding at least 2 layers of 2" of poly-iso above the structural deck and filling the 8" r...

Full article: http://www.greenbuildingadvisor.com/community/forum/energ...

Tweets

Air sealing, flashing questions #green

Air sealing, flashing questions #green

greenbuildingadvisor.com 25 Aug '13, 10pm

I have to say that reading GBA for 4 years certainly helps when you build your own house (my brother's house, really), but...

best choice strategy to re-insulate existing un...

greenbuildingadvisor.com 22 Aug '13, 11pm

Hey follks, I'm currently working on a remodel of a 1920s stud-framed house, about 1200 sq ft, in climate zone 6 (Montreal...

Venting and insulation for cathedral ceilings #green

Venting and insulation for cathedral ceilings #...

greenbuildingadvisor.com 02 Sep '13, 9pm

We're in Hamilton, Ontario, trying to insulate our attic which has cathedral ceilings. Previous owners had more or less sh...

Any advice for installing skylights in an unven...

greenbuildingadvisor.com 17 Aug '13, 8pm

Hi I'm getting set to install 2 velux skylights in the roof of my addition. Its a shed roof style addition that I built us...

Moisture issue with improperly dense packed cei...

greenbuildingadvisor.com 20 Aug '13, 7pm

Does anyone have any idea what the chances are of a moisture issue(s) occurring in an unvented vaulted ceiling where the c...

Once again, its not the fun stuff like a kitche...

greenbuildingadvisor.com 28 Aug '13, 9pm

The research results correlate well with long-standing advice on air-sealing. “When you stack up these results with typica...

Energy Nerd: Getting the Biggest Bang for Your ...

greenbuildingadvisor.com 23 Aug '13, 10am

The researchers did not test leaks around floor-mounted duct boots. The researchers did not test leaks at cracks between c...